Panel filters
Flat pleated panels in a frame, for general ventilation and pre-filtration.
Air filters · TAF · Great Britain
aksutec is the exclusive GB representative of 5M Mühendislik – TAF (Turkish Air Filter), a Turkish manufacturer of air filters. From our base in Enfield, North London, we supply panel, bag, HEPA, compact, activated carbon, high-temperature, metal and fan-coil filters, in standard and custom sizes.
Send the size, the class and the quantity. A person checks the request against the TAF range and replies with what matches. This is not an automatic stock search.
Eight filter types
Dust points to panel, bag or compact filters. Cleanroom and hospital air points to HEPA. Odour and gas point to activated carbon, heat to high-temperature filters, and grease or coarse debris to washable metal filters. Each type has its own page with construction, uses and questions.

Flat pleated panels in a frame, for general ventilation and pre-filtration.

Deep pockets of filter media on a header frame, for larger airflows.

Mini-pleat packs for high-efficiency filtration, specified to EN 1822 class.

V-bank construction that packs a large media area into a short housing depth.
A carbon bed between media layers, for odour and gas-phase filtration.
Deep-pleat media with metal separators in a steel frame, for heat.

Layered mesh in a frame that can be cleaned and used again.
Thin pleated panels cut to fit fan-coil unit housings.
Reading a class
ISO 16890 classifies general ventilation filters by the size of the particles they capture. EN 1822, aligned with ISO 29463, classifies high-efficiency filters. The older EN 779 names, such as G4 and F7, still appear on drawings and old orders. Tell us whichever you have and we will match it, and we confirm the exact rating for your order.
| Standard | Covers | Groups or classes |
|---|---|---|
| ISO 16890 | General ventilation filters | ISO Coarse, ePM10, ePM2.5, ePM1 |
| EN 1822 | High-efficiency filters | E10 to E12, H13 and H14 (HEPA), U15 to U17 |
| EN 779 (withdrawn) | Older general filter names | G1 to G4, M5 and M6, F7 to F9 |
A gas-phase filter such as activated carbon is not classed by particle size at all. For carbon we need the gas or odour you are removing instead.
How to specify
Send these four and a person can check the request. If one is missing, send what you have: a photo of the old filter and its label often fills the gaps.
Width × height × depth in millimetres, for example 592 × 592 × 292. Measure the frame of the old filter or the opening it sits in. If the old filter has been squeezed into its slot, measure the slot. Standard and custom sizes are both possible, so send exact figures.
Tell us the class you need (ISO 16890 or EN 1822). If your paperwork uses the older EN 779 names, such as G4 or F7, send those and we will match them. If you do not know the class, send the label of the filter you use now.
How many of each size, and whether this is a one-off order or a regular one. A mixed list is fine, with one line per size.
What the filter sits in, such as an air handling unit, a fan-coil unit, an oven or a cleanroom ceiling, and the airflow in cubic metres per hour if you have it. Add the temperature, the humidity and anything unusual in the air, such as grease, oil or chemicals.
A person checks every request. We tell you what matches, what differs and what we could not confirm, and we confirm the exact rating for your order.
Filter desk
The request form is set to air filters. Choose a type, or leave it on Not sure and describe where the filter goes. Add a photo of the old filter or of its label if you have one.
We check the request against the TAF range and tell you what matches, what differs and what we could not confirm. We reply by phone, WhatsApp or email, whichever you give us.
Questions
It depends on what you are removing and what your housing can take. Dust and pollen in ventilation air point to panel, bag or compact filters. Cleanroom and hospital air points to HEPA. Odour or gas points to activated carbon. Heat points to high-temperature filters, and grease or coarse debris points to washable metal filters. If you are not sure, send what the unit is, where it sits and what the old filter looked like, and a person will suggest a type.
ISO 16890 classifies general ventilation filters by the particle size groups they capture: ISO Coarse, ePM10, ePM2.5 and ePM1. EN 1822 classifies high-efficiency filters, from E10 to U17, with H13 and H14 being the usual HEPA classes. Older enquiries often still use EN 779 names such as G4 or F7. Tell us whichever you have and we will match it to a current class and confirm the exact rating for your order.
Both. Many general ventilation filters follow common modular sizes, and many installations do not, so send the width, height and depth in millimetres, measured from the frame or the housing. We will tell you if your size is a standard one or needs to be made to order.
The filters are made by 5M Mühendislik, trading as TAF (Turkish Air Filter), in Türkiye. aksutec is the representative for Great Britain, based in Enfield, North London, so you deal with a UK contact for the enquiry, the quotation and the delivery.
Send the filter type if you know it, the size as width × height × depth in millimetres, the class you need, the quantity and a line about the application or airflow. A photo of the old filter, or of its label, speeds this up. A person checks the request; there is no automatic price lookup.
Usually, yes. Send the label or the manufacturer reference, and the measured size. We compare the construction, frame, class and depth with what the TAF range offers and tell you what matches, what differs and what we could not confirm.