Fan-coil filters

A fan-coil filter is a thin pleated panel made to fit the housing of a fan-coil unit. A fan-coil unit has a small fan, a coil for heating or cooling, and a thin filter in the air return. The filter keeps dust and fibres off the coil and the fan, and it holds back some of what the room generates.

Drawing
AKS-AF-FAN-COIL
Sheet
14 / 17
Rev
2026-11-16
Cross-section of a fan-coil filterAIRFLOWHTHIN PLEATED PANELCOILFANSECTION A–A · FAN-COIL
Section through a fan-coil filter. A thin pleated panel sits in the air return of a fan-coil unit, in front of the fan and the coil. The unit has little room, so the panel is thin and made to the measured size of the slot.

Construction

How a fan-coil filter is built.

The panel is thin because there is little room in the unit, and it is often made to a custom size because the filter slot differs between manufacturers and models. The media is a pleated synthetic material in a frame. Most units run a low-pressure fan, so the filter has to have a low pressure drop or the airflow falls and the coil performs worse.

Fan-coil filters at a glance
ConstructionThin pleated panel cut to the slot of a fan-coil unit
SizesOften non-standard: measure the slot
Classes to ask aboutISO Coarse and ePM10, to protect the coil and the fan
WatchKeep the resistance low, as the fan has little pressure in hand
What we need from youLength × width × thickness in mm, unit make and model, quantity

Performance and care

What to expect, and how to look after it.

Performance and limits

These filters sit in the coarse and ePM10 groups of ISO 16890, as the aim is to protect the unit and the coil and to catch visible dust, not to deliver a clean environment. If the room needs fine filtration, the central air handling unit is the place for it, and the fan-coil filter protects the coil.

Fitting and replacement

Replacement is frequent and rarely done on a schedule. A blocked fan-coil filter makes the unit noisy, reduces its output, and lets the coil foul. A fixed interval set by the building and a record of the sizes in each room make the job a lot easier. We confirm the exact rating for your order.

Where it is used

Where fan-coil filters are used.

  • Hotels and serviced apartments

    A fan-coil unit in each room recirculates the air through a thin filter that needs regular replacement.

  • Offices with ceiling cassettes and wall units

    Fan-coil units sit in the occupied space and move air all day, so the filters load quickly.

  • Hospitals and care homes

    Room fan-coil units with a filter that keeps the coil clean and the room air acceptable between full plant servicing.

  • Retail and leisure

    Fan-coil units in shops, gyms and restaurants, where footfall, fibres and cooking aerosols settle in the filter.

  • Building refurbishment

    Older fan-coil units often have non-standard filter slots and need a filter made to the measured size.

Choosing

This type, or a different one.

Choose it when

Choose a fan-coil filter when the unit takes a thin panel in the return and you want a clean coil and a steady airflow. It is the right shape and thickness for the job.

Choose another type when

Choose a panel filter when the housing is a normal filter rack, a bag or compact filter for a central air handling unit, and HEPA where a room class is required, usually through a ceiling terminal.

How to specify

Four details are enough to price a filter.

Send these four and a person can check the request. If one is missing, send what you have: a photo of the old filter and its label often fills the gaps.

  1. 01

    Size

    Width × height × depth in millimetres, for example 592 × 592 × 292. Measure the frame of the old filter or the opening it sits in. If the old filter has been squeezed into its slot, measure the slot. Standard and custom sizes are both possible, so send exact figures.

  2. 02

    Class

    Tell us the class you need (ISO 16890 or EN 1822). If your paperwork uses the older EN 779 names, such as G4 or F7, send those and we will match them. If you do not know the class, send the label of the filter you use now.

  3. 03

    Quantity

    How many of each size, and whether this is a one-off order or a regular one. A mixed list is fine, with one line per size.

  4. 04

    Application and airflow

    What the filter sits in, such as an air handling unit, a fan-coil unit, an oven or a cleanroom ceiling, and the airflow in cubic metres per hour if you have it. Add the temperature, the humidity and anything unusual in the air, such as grease, oil or chemicals.

A person checks every request. We tell you what matches, what differs and what we could not confirm, and we confirm the exact rating for your order.

Filter desk

Ask about fan-coil filters. A person replies.

The request form below is set to air filters and to this type. Give the size, the class and the quantity, add a photo of the old filter if you have one, and send it. A person reads every request, checks the details against the TAF range and replies by phone, WhatsApp or email.

Not sure this is the right type? Leave it as it is and say what the filter is for. We will tell you if another type fits better.

What do you need?

Send a part number or a photo of the rating plate. A person checks every request; this is not an automatic stock search.

Line stopped? Call first. We will pick up the request below too.

Robot part details
Rating plateoptional
Add a photo of the rating plateJPEG, PNG, WebP or HEIC, up to 8 MB.
More detail (optional)
Machining, cell or fixture details
Drawingoptional
Attach a drawingPDF, STEP, STP, DXF, DWG, PNG or JPG, up to 8 MB.
More detail (optional)
Air filter details
More detail (optional)

For example G4, F7 or H13.

Your details
Add a message

Files up to 8 MB. We use your details only to answer this request.

Questions

Fan-coil filters: common questions.

How do I measure a fan-coil filter?

Take the width, length and thickness of the old filter in millimetres, and check them against the slot in the unit. Measure in more than one place, because the old filter may be squeezed or worn. A photo of the unit, its label and the old filter lets us check the fit.

Can you supply non-standard sizes?

Fan-coil filters are often non-standard, so send the measured size and the quantity. We will tell you if the size is a standard one or needs to be made to order. For a building with many different units, a list with one line per size saves time.

How often should fan-coil filters be changed?

More often than most people expect. Fan-coil units take the air from the occupied space, which carries fibres and dust. For many buildings, a check every few months is sensible, with the interval set by what you find. A dirty filter is a sign the interval is too long.

Does the filter class affect performance?

Yes. A finer class has a higher resistance, and a low-pressure fan can lose airflow. Keep to the class the unit was designed for unless the manufacturer says otherwise. Send the unit make and model with your enquiry and we will help you stay within it.